TY - JOUR
T1 - A microbiology-based multi-parametric approach towards assessing biological stability in drinking water distribution networks
AU - Lautenschläger, Karin
AU - Hwang, Chiachi
AU - Liu, Wentso
AU - Boon, Nico
AU - Köster, Oliver
AU - Vrouwenvelder, Johannes S.
AU - Egli, Thomas
AU - Hammes, Frederik A.
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledgements: We would like to thank Fangqiong Ling, and Hideyuki Tamaki for their help with the microbial community analysis. We are grateful to the financial support of the EU project TECHNEAU (018320).
PY - 2013/6
Y1 - 2013/6
N2 - Biological stability of drinking water implies that the concentration of bacterial cells and composition of the microbial community should not change during distribution. In this study, we used a multi-parametric approach that encompasses different aspects of microbial water quality including microbial growth potential, microbial abundance, and microbial community composition, to monitor biological stability in drinking water of the non-chlorinated distribution system of Zürich. Drinking water was collected directly after treatment from the reservoir and in the network at several locations with varied average hydraulic retention times (6-52h) over a period of four months, with a single repetition two years later. Total cell concentrations (TCC) measured with flow cytometry remained remarkably stable at 9.5 (±0.6)×104cells/ml from water in the reservoir throughout most of the distribution network, and during the whole time period. Conventional microbial methods like heterotrophic plate counts, the concentration of adenosine tri-phosphate, total organic carbon and assimilable organic carbon remained also constant. Samples taken two years apart showed more than 80% similarity for the microbial communities analysed with denaturing gradient gel electrophoresis and 454 pyrosequencing. Only the two sampling locations with the longest water retention times were the exceptions and, sofar for unknown reasons, recorded a slight but significantly higher TCC (1.3(±0.1)×105cells/ml) compared to the other locations. This small change in microbial abundance detected by flow cytometry was also clearly observed in a shift in the microbial community profiles to a higher abundance of members from the Comamonadaceae (60% vs. 2% at other locations). Conventional microbial detection methods were not able to detect changes as observed with flow cytometric cell counts and microbial community analysis. Our findings demonstrate that the multi-parametric approach used provides a powerful and sensitive tool to assess and evaluate biological stability and microbial processes in drinking water distribution systems. © 2013 Elsevier Ltd.
AB - Biological stability of drinking water implies that the concentration of bacterial cells and composition of the microbial community should not change during distribution. In this study, we used a multi-parametric approach that encompasses different aspects of microbial water quality including microbial growth potential, microbial abundance, and microbial community composition, to monitor biological stability in drinking water of the non-chlorinated distribution system of Zürich. Drinking water was collected directly after treatment from the reservoir and in the network at several locations with varied average hydraulic retention times (6-52h) over a period of four months, with a single repetition two years later. Total cell concentrations (TCC) measured with flow cytometry remained remarkably stable at 9.5 (±0.6)×104cells/ml from water in the reservoir throughout most of the distribution network, and during the whole time period. Conventional microbial methods like heterotrophic plate counts, the concentration of adenosine tri-phosphate, total organic carbon and assimilable organic carbon remained also constant. Samples taken two years apart showed more than 80% similarity for the microbial communities analysed with denaturing gradient gel electrophoresis and 454 pyrosequencing. Only the two sampling locations with the longest water retention times were the exceptions and, sofar for unknown reasons, recorded a slight but significantly higher TCC (1.3(±0.1)×105cells/ml) compared to the other locations. This small change in microbial abundance detected by flow cytometry was also clearly observed in a shift in the microbial community profiles to a higher abundance of members from the Comamonadaceae (60% vs. 2% at other locations). Conventional microbial detection methods were not able to detect changes as observed with flow cytometric cell counts and microbial community analysis. Our findings demonstrate that the multi-parametric approach used provides a powerful and sensitive tool to assess and evaluate biological stability and microbial processes in drinking water distribution systems. © 2013 Elsevier Ltd.
UR - http://hdl.handle.net/10754/562789
UR - https://linkinghub.elsevier.com/retrieve/pii/S0043135413001589
UR - http://www.scopus.com/inward/record.url?scp=84876736576&partnerID=8YFLogxK
U2 - 10.1016/j.watres.2013.03.002
DO - 10.1016/j.watres.2013.03.002
M3 - Article
C2 - 23557697
SN - 0043-1354
VL - 47
SP - 3015
EP - 3025
JO - Water Research
JF - Water Research
IS - 9
ER -