TY - JOUR
T1 - A MXene-Based Wearable Biosensor System for High-Performance In Vitro Perspiration Analysis
AU - Lei, Yongjiu
AU - zhao, Wenli
AU - Zhang, Yizhou
AU - Jiang, Qiu
AU - He, Jr-Hau
AU - Baeumner, Antje J
AU - Wolfbeis, Otto S
AU - Wang, Zhong Lin
AU - Salama, Khaled N.
AU - Alshareef, Husam N.
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledged KAUST grant number(s): CRF-2015-SENSORS-2709
Acknowledgements: The research reported in this manuscript was supported by funding from the King Abdullah University of Science and Technology (KAUST) under the Sensors Initiative (CRF-2015-SENSORS-2709). The authors thank the Advanced Nanofabrication, Imaging and Characterization Laboratory at KAUST for their excellent support. Y.L. thanks the help from Dr. Yunpei Zhu (KAUST) and Dr. Kang Hyuck Lee (KAUST). Figures 1, 2a, and 3a were produced by Xavier Pita, a scientific illustrator at the King Abdullah University of Science and Technology (KAUST).
PY - 2019/4/8
Y1 - 2019/4/8
N2 - Wearable electrochemical biosensors for sweat analysis present a promising means for noninvasive biomarker monitoring. However, sweat-based sensing still poses several challenges, including easy degradation of enzymes and biomaterials with repeated testing, limited detection range and sensitivity of enzyme-based biosensors caused by oxygen deficiency in sweat, and poor shelf life of sensors using all-in-one working electrodes patterned by traditional techniques (e.g., electrodeposition and screen printing). Herein, a stretchable, wearable, and modular multifunctional biosensor is developed, incorporating a novel MXene/Prussian blue (Ti3 C2 Tx /PB) composite designed for durable and sensitive detection of biomarkers (e.g., glucose and lactate) in sweat. A unique modular design enables a simple exchange of the specific sensing electrode to target the desired analytes. Furthermore, an implemented solid-liquid-air three-phase interface design leads to superior sensor performance and stability. Typical electrochemical sensitivities of 35.3 µA mm-1 cm-2 for glucose and 11.4 µA mm-1 cm-2 for lactate are achieved using artificial sweat. During in vitro perspiration monitoring of human subjects, the physiochemistry signals (glucose and lactate level) can be measured simultaneously with high sensitivity and good repeatability. This approach represents an important step toward the realization of ultrasensitive enzymatic wearable biosensors for personalized health monitoring.
AB - Wearable electrochemical biosensors for sweat analysis present a promising means for noninvasive biomarker monitoring. However, sweat-based sensing still poses several challenges, including easy degradation of enzymes and biomaterials with repeated testing, limited detection range and sensitivity of enzyme-based biosensors caused by oxygen deficiency in sweat, and poor shelf life of sensors using all-in-one working electrodes patterned by traditional techniques (e.g., electrodeposition and screen printing). Herein, a stretchable, wearable, and modular multifunctional biosensor is developed, incorporating a novel MXene/Prussian blue (Ti3 C2 Tx /PB) composite designed for durable and sensitive detection of biomarkers (e.g., glucose and lactate) in sweat. A unique modular design enables a simple exchange of the specific sensing electrode to target the desired analytes. Furthermore, an implemented solid-liquid-air three-phase interface design leads to superior sensor performance and stability. Typical electrochemical sensitivities of 35.3 µA mm-1 cm-2 for glucose and 11.4 µA mm-1 cm-2 for lactate are achieved using artificial sweat. During in vitro perspiration monitoring of human subjects, the physiochemistry signals (glucose and lactate level) can be measured simultaneously with high sensitivity and good repeatability. This approach represents an important step toward the realization of ultrasensitive enzymatic wearable biosensors for personalized health monitoring.
UR - http://hdl.handle.net/10754/652454
UR - https://onlinelibrary.wiley.com/doi/full/10.1002/smll.201901190
UR - http://www.scopus.com/inward/record.url?scp=85064005013&partnerID=8YFLogxK
U2 - 10.1002/smll.201901190
DO - 10.1002/smll.201901190
M3 - Article
C2 - 30957964
SN - 1613-6810
VL - 15
SP - 1901190
JO - Small
JF - Small
IS - 19
ER -