TY - JOUR
T1 - A novel approach to calibrate the Hemodynamic Model using functional Magnetic Resonance Imaging (fMRI) measurements
AU - Khoram, Nafiseh
AU - Zayane, Chadia
AU - Djellouli, Rabia
AU - Laleg-Kirati, Taous-Meriem
N1 - KAUST Repository Item: Exported on 2020-10-01
PY - 2016/1/21
Y1 - 2016/1/21
N2 - Background
The calibration of the hemodynamic model that describes changes in blood flow and blood oxygenation during brain activation is a crucial step for successfully monitoring and possibly predicting brain activity. This in turn has the potential to provide diagnosis and treatment of brain diseases in early stages.
New Method
We propose an efficient numerical procedure for calibrating the hemodynamic model using some fMRI measurements. The proposed solution methodology is a regularized iterative method equipped with a Kalman filtering-type procedure. The Newton component of the proposed method addresses the nonlinear aspect of the problem. The regularization feature is used to ensure the stability of the algorithm. The Kalman filter procedure is incorporated here to address the noise in the data.
Results
Numerical results obtained with synthetic data as well as with real fMRI measurements are presented to illustrate the accuracy, robustness to the noise, and the cost-effectiveness of the proposed method.
Comparison with Existing Method(s)
We present numerical results that clearly demonstrate that the proposed method outperforms the Cubature Kalman Filter (CKF), one of the most prominent existing numerical methods.
Conclusion
We have designed an iterative numerical technique, called the TNM-CKF algorithm, for calibrating the mathematical model that describes the single-event related brain response when fMRI measurements are given. The method appears to be highly accurate and effective in reconstructing the BOLD signal even when the measurements are tainted with high noise level (as high as 30%).
AB - Background
The calibration of the hemodynamic model that describes changes in blood flow and blood oxygenation during brain activation is a crucial step for successfully monitoring and possibly predicting brain activity. This in turn has the potential to provide diagnosis and treatment of brain diseases in early stages.
New Method
We propose an efficient numerical procedure for calibrating the hemodynamic model using some fMRI measurements. The proposed solution methodology is a regularized iterative method equipped with a Kalman filtering-type procedure. The Newton component of the proposed method addresses the nonlinear aspect of the problem. The regularization feature is used to ensure the stability of the algorithm. The Kalman filter procedure is incorporated here to address the noise in the data.
Results
Numerical results obtained with synthetic data as well as with real fMRI measurements are presented to illustrate the accuracy, robustness to the noise, and the cost-effectiveness of the proposed method.
Comparison with Existing Method(s)
We present numerical results that clearly demonstrate that the proposed method outperforms the Cubature Kalman Filter (CKF), one of the most prominent existing numerical methods.
Conclusion
We have designed an iterative numerical technique, called the TNM-CKF algorithm, for calibrating the mathematical model that describes the single-event related brain response when fMRI measurements are given. The method appears to be highly accurate and effective in reconstructing the BOLD signal even when the measurements are tainted with high noise level (as high as 30%).
UR - http://hdl.handle.net/10754/594713
UR - http://linkinghub.elsevier.com/retrieve/pii/S0165027016000327
UR - http://www.scopus.com/inward/record.url?scp=84956643751&partnerID=8YFLogxK
U2 - 10.1016/j.jneumeth.2016.01.015
DO - 10.1016/j.jneumeth.2016.01.015
M3 - Article
C2 - 26802187
SN - 0165-0270
VL - 262
SP - 93
EP - 109
JO - Journal of Neuroscience Methods
JF - Journal of Neuroscience Methods
ER -