N2 - Goal: Fractional-order Windkessel model is proposed to describe the aortic input impedance. Compared with the conventional arterial Windkessel, the main advantage of the proposed model is the consideration of the viscoelastic nature of the arterial wall using the fractional-order capacitor (FOC). Methods: The proposed model, along with the standard two-element Windkessel, three-element Windkessel, and the viscoelastic Windkessel models, are assessed and compared using in-silico data. Results: The results show that the fractional-order model fits better the moduli of the aortic input impedance and fairly approximates the phase angle. In addition, by its very nature, the pseudo-capacitance of FOC makes the proposed model's dynamic compliance complex and frequency-dependent. Conclusion: The analysis of the proposed fractional-order model indicates that fractional-order impedance yields a powerful tool for a flexible characterization of the arterial hemodynamics.
AB - Goal: Fractional-order Windkessel model is proposed to describe the aortic input impedance. Compared with the conventional arterial Windkessel, the main advantage of the proposed model is the consideration of the viscoelastic nature of the arterial wall using the fractional-order capacitor (FOC). Methods: The proposed model, along with the standard two-element Windkessel, three-element Windkessel, and the viscoelastic Windkessel models, are assessed and compared using in-silico data. Results: The results show that the fractional-order model fits better the moduli of the aortic input impedance and fairly approximates the phase angle. In addition, by its very nature, the pseudo-capacitance of FOC makes the proposed model's dynamic compliance complex and frequency-dependent. Conclusion: The analysis of the proposed fractional-order model indicates that fractional-order impedance yields a powerful tool for a flexible characterization of the arterial hemodynamics.
UR - http://hdl.handle.net/10754/662618
UR - https://ieeexplore.ieee.org/document/9076293/
U2 - 10.1109/OJEMB.2020.2988179
DO - 10.1109/OJEMB.2020.2988179
M3 - Article
SN - 2644-1276
SP - 1
EP - 1
JO - IEEE Open Journal of Engineering in Medicine and Biology
JF - IEEE Open Journal of Engineering in Medicine and Biology
ER -