TY - JOUR
T1 - Cavity-enhanced absorption sensor for carbon monoxide in a rapid compression machine
AU - Nasir, Ehson Fawad
AU - Farooq, Aamir
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledged KAUST grant number(s): BAS/1/1300-01-01
Acknowledgements: Research reported in this publication was supported by funding from the Office of Sponsored Research at King Abdullah University of Science and Technology (KAUST) (BAS/1/1300-01-01).
PY - 2018/12/14
Y1 - 2018/12/14
N2 - A sensor based on cavity-enhanced absorption spectroscopy (CEAS) was implemented for the first time in a rapid compression machine (RCM) for carbon monoxide concentration measurements. The sensor consisted of a pulsed quantum cascade laser (QCL) coupled to a low-finesse cavity in the RCM using an off-axis alignment. The QCL was tuned near 4.89μm to probe the P(23) ro-vibrational line of CO. The pulsed mode operation resulted in rapid frequency down-chirp (6.52 cm-1/μs) within the pulse as well as a high time resolution (10 μs). The combination of rapid frequency down-chirp and off-axis cavity alignment enabled a near complete suppression of the cavity coupling noise. A CEAS gain factor of 133 was demonstrated in experiments, resulting in a much lower noise-equivalent detection limit than a single-pass arrangement. The sensor thus presents many opportunities for measuring CO formation at low temperatures and for studying kinetics using dilute reactive environments; one such application is demonstrated in this work using dilute n-heptane/air mixtures in the RCM. The formation of CO during first-stage ignition of n-heptane was measured over 802-899K at a nominal pressure of 10bar. These conditions correspond to the NTC region of n-heptane and such results provide useful metrics to test and compare the predictions of low-temperature heat release by different kinetic models.
AB - A sensor based on cavity-enhanced absorption spectroscopy (CEAS) was implemented for the first time in a rapid compression machine (RCM) for carbon monoxide concentration measurements. The sensor consisted of a pulsed quantum cascade laser (QCL) coupled to a low-finesse cavity in the RCM using an off-axis alignment. The QCL was tuned near 4.89μm to probe the P(23) ro-vibrational line of CO. The pulsed mode operation resulted in rapid frequency down-chirp (6.52 cm-1/μs) within the pulse as well as a high time resolution (10 μs). The combination of rapid frequency down-chirp and off-axis cavity alignment enabled a near complete suppression of the cavity coupling noise. A CEAS gain factor of 133 was demonstrated in experiments, resulting in a much lower noise-equivalent detection limit than a single-pass arrangement. The sensor thus presents many opportunities for measuring CO formation at low temperatures and for studying kinetics using dilute reactive environments; one such application is demonstrated in this work using dilute n-heptane/air mixtures in the RCM. The formation of CO during first-stage ignition of n-heptane was measured over 802-899K at a nominal pressure of 10bar. These conditions correspond to the NTC region of n-heptane and such results provide useful metrics to test and compare the predictions of low-temperature heat release by different kinetic models.
UR - http://hdl.handle.net/10754/660230
UR - https://linkinghub.elsevier.com/retrieve/pii/S1540748918300154
UR - http://www.scopus.com/inward/record.url?scp=85048525719&partnerID=8YFLogxK
U2 - 10.1016/j.proci.2018.05.015
DO - 10.1016/j.proci.2018.05.015
M3 - Article
SN - 1540-7489
VL - 37
SP - 1297
EP - 1304
JO - Proceedings of the Combustion Institute
JF - Proceedings of the Combustion Institute
IS - 2
ER -