TY - JOUR
T1 - CO2/CH4 Pure- and Mixed-Gas Dilation and Sorption in Thin (∼500 nm) and Ultrathin (∼50 nm) Polymers of Intrinsic Microporosity
AU - Ogieglo, Wojciech
AU - Genduso, Giuseppe
AU - Rubner, Jens
AU - Hofmann-Préveraud de Vaumas, Jacques
AU - Wessling, Matthias
AU - Pinnau, Ingo
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledged KAUST grant number(s): BAS/1/1323-01-01
Acknowledgements: This work was supported by funding (BAS/1/1323-01-01) from King Abdullah University of Science and Technology (KAUST).
PY - 2020/9/23
Y1 - 2020/9/23
N2 - In this work, we present (i) the dilation and refractive index variation associated with changes in film density and (ii) gas uptake of pure CO2 and CH4, as well as their equimolar mixture in thin films of two polymers of intrinsic microporosity (PIMs), that is, PIM-1 and poly(trimethylsilyl)propyne (PTMSP). A conventional low-free-volume glassy polymer, cellulose triacetate, was also investigated as the reference material. All experiments were performed with ∼50 and ∼500 nm-thick films up to partial pressures of 25 bar using in situ interference-enhanced spectroscopic ellipsometry. In all cases, film thickness reduction promoted the collapse of the frozen-in free volume. Particularly for thin PIM-1 and PTMSP films, the CO2 and CH4 pure-gas uptakes were generally lower than in bulk samples. In the most extreme case of the ultrathin ∼50 nm PTMSP film, we could detect a strikingly similar qualitative behavior to the penetrant partial molar volume and dilation in rubbery polymers. Remarkably, in PIM-1, the collapse of the frozen-in free volume seemed to be opposed by its ultra-micropores (10 Å). In mixed-gas experiments, the refractive index response of all investigated films closely followed the trend observed during CO2 pure-gas sorption. In both thickness ranges and throughout the entire pressure range, the samples dilated less in the multicomponent environment than under the corresponding ideal pure-gas conditions. We found this phenomenon consistent with the pure- and mixed-gas uptake behavior of PIM-1 and PTMSP bulk films reported in the literature.
AB - In this work, we present (i) the dilation and refractive index variation associated with changes in film density and (ii) gas uptake of pure CO2 and CH4, as well as their equimolar mixture in thin films of two polymers of intrinsic microporosity (PIMs), that is, PIM-1 and poly(trimethylsilyl)propyne (PTMSP). A conventional low-free-volume glassy polymer, cellulose triacetate, was also investigated as the reference material. All experiments were performed with ∼50 and ∼500 nm-thick films up to partial pressures of 25 bar using in situ interference-enhanced spectroscopic ellipsometry. In all cases, film thickness reduction promoted the collapse of the frozen-in free volume. Particularly for thin PIM-1 and PTMSP films, the CO2 and CH4 pure-gas uptakes were generally lower than in bulk samples. In the most extreme case of the ultrathin ∼50 nm PTMSP film, we could detect a strikingly similar qualitative behavior to the penetrant partial molar volume and dilation in rubbery polymers. Remarkably, in PIM-1, the collapse of the frozen-in free volume seemed to be opposed by its ultra-micropores (10 Å). In mixed-gas experiments, the refractive index response of all investigated films closely followed the trend observed during CO2 pure-gas sorption. In both thickness ranges and throughout the entire pressure range, the samples dilated less in the multicomponent environment than under the corresponding ideal pure-gas conditions. We found this phenomenon consistent with the pure- and mixed-gas uptake behavior of PIM-1 and PTMSP bulk films reported in the literature.
UR - http://hdl.handle.net/10754/665324
UR - https://pubs.acs.org/doi/10.1021/acs.macromol.0c01163
U2 - 10.1021/acs.macromol.0c01163
DO - 10.1021/acs.macromol.0c01163
M3 - Article
SN - 0024-9297
JO - Macromolecules
JF - Macromolecules
ER -