TY - JOUR
T1 - Development of an avidin sensor based on the poly(methoxy amino-β-styryl terthiophene)-coated glassy carbon electrode
AU - Mehenni, Hakim
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledgements: This work was supported by the National Institute of Scientific Research (INRS) and the Natural Sciences and Engineering Research Council of Canada (NSERC).
PY - 2012/3
Y1 - 2012/3
N2 - In this study, a simple and direct biosensor was proposed, which was based on biotin immobilized onto a conducting polymer-coated electrode, for the determination of avidin, a highly stable glycoprotein found in egg whites. Biotin was immobilized onto the electrode by covalent coupling to the primary amine group on poly-3′-(2-methoxy-5-amino-β-styryl)-(2,2′: 5′,2″-terthiophene) (PMAST), and the biotin-avidin interaction was monitored by square-wave voltammetry. Incubation of the PMAST/biotin-modified coated electrode with avidin in a phosphate-buffered saline solution caused a significant change to its square-wave voltammogram, which was explained by the binding of avidin by biotin, and resulted in restricted ion transfer to and from the conducting polymer. This change was then utilized to determine avidin. Importantly, we found a linear relationship for the avidin sensor in the range of 4 × 10 -14 to 3 × 10 -4 mol/L, and the detection limit was determined to be approximately 10 -14 mol/L. © 2012 Published by NRC Research Press.
AB - In this study, a simple and direct biosensor was proposed, which was based on biotin immobilized onto a conducting polymer-coated electrode, for the determination of avidin, a highly stable glycoprotein found in egg whites. Biotin was immobilized onto the electrode by covalent coupling to the primary amine group on poly-3′-(2-methoxy-5-amino-β-styryl)-(2,2′: 5′,2″-terthiophene) (PMAST), and the biotin-avidin interaction was monitored by square-wave voltammetry. Incubation of the PMAST/biotin-modified coated electrode with avidin in a phosphate-buffered saline solution caused a significant change to its square-wave voltammogram, which was explained by the binding of avidin by biotin, and resulted in restricted ion transfer to and from the conducting polymer. This change was then utilized to determine avidin. Importantly, we found a linear relationship for the avidin sensor in the range of 4 × 10 -14 to 3 × 10 -4 mol/L, and the detection limit was determined to be approximately 10 -14 mol/L. © 2012 Published by NRC Research Press.
UR - http://hdl.handle.net/10754/562113
UR - http://www.nrcresearchpress.com/doi/10.1139/v11-160
UR - http://www.scopus.com/inward/record.url?scp=84858242963&partnerID=8YFLogxK
U2 - 10.1139/v11-160
DO - 10.1139/v11-160
M3 - Article
SN - 0008-4042
VL - 90
SP - 271
EP - 277
JO - Canadian Journal of Chemistry
JF - Canadian Journal of Chemistry
IS - 3
ER -