TY - JOUR
T1 - Effects of sickle cell trait and hemoglobin C trait on determinations of HbA(1c) by an immunoassay method
AU - Roberts, William L.
AU - Mccraw, Mary
AU - Cook, Curtiss B.
N1 - Generated from Scopus record by KAUST IRTS on 2023-09-20
PY - 1998/11/7
Y1 - 1998/11/7
N2 - OBJECTIVE - A number of studies, including the Diabetes Control and Complications Trial (DCCT), have shown that good glycemic control, as assessed by GHb measurements, can reduce the chronic complications of diabetes. The National Glycohemoglobin Standardization Program (NGSP) was established to insure that GHb measurements by different methods were comparable and could be related to the candidate reference method used in the DCCT. The measurement of HbA(1c) in patients with Hb variants is one area not directly addressed by the NGSP. Therefore, we assessed the comparability of two DCCT-traceable methods in samples with Hb variants. RESEARCH DESIGN AND METHODS - Samples containing HbAA, HbAC, and HbAS were collected from diabetic and nondiabetic patients. HbA(1c) concentrations were measured by a high-performance liquid chromatography method (Bio-Rad Diamat) and an immunoassay that is suitable for use in a physician's office (Bayer DCA 2000). RESULTS - The two methods compared well for samples with HbAA and HbAS. However, for samples containing HbAC the immunoassay method showed relative positive biases of 8.4 and 10.4% at HbA(1c) levels of 7 and 9%, respectively, such that the two methods would not be judged comparable according to NGSP guidelines. CONCLUSIONS - The DCA 2000 HbA(1c) immunoassay method showed significant positive bias in patients with HbC trait. One possible clinical implication of this overestimation is overly rigorous glycemic control with a concomitant increase in hypoglycemia. This may be especially important in certain ethnic populations, such as African- Americans, who have a relatively high prevalence of HbC trait.
AB - OBJECTIVE - A number of studies, including the Diabetes Control and Complications Trial (DCCT), have shown that good glycemic control, as assessed by GHb measurements, can reduce the chronic complications of diabetes. The National Glycohemoglobin Standardization Program (NGSP) was established to insure that GHb measurements by different methods were comparable and could be related to the candidate reference method used in the DCCT. The measurement of HbA(1c) in patients with Hb variants is one area not directly addressed by the NGSP. Therefore, we assessed the comparability of two DCCT-traceable methods in samples with Hb variants. RESEARCH DESIGN AND METHODS - Samples containing HbAA, HbAC, and HbAS were collected from diabetic and nondiabetic patients. HbA(1c) concentrations were measured by a high-performance liquid chromatography method (Bio-Rad Diamat) and an immunoassay that is suitable for use in a physician's office (Bayer DCA 2000). RESULTS - The two methods compared well for samples with HbAA and HbAS. However, for samples containing HbAC the immunoassay method showed relative positive biases of 8.4 and 10.4% at HbA(1c) levels of 7 and 9%, respectively, such that the two methods would not be judged comparable according to NGSP guidelines. CONCLUSIONS - The DCA 2000 HbA(1c) immunoassay method showed significant positive bias in patients with HbC trait. One possible clinical implication of this overestimation is overly rigorous glycemic control with a concomitant increase in hypoglycemia. This may be especially important in certain ethnic populations, such as African- Americans, who have a relatively high prevalence of HbC trait.
UR - https://diabetesjournals.org/care/article/21/6/983/19473/Effects-of-Sickle-Cell-Trait-and-Hemoglobin-C
UR - http://www.scopus.com/inward/record.url?scp=0031738645&partnerID=8YFLogxK
U2 - 10.2337/diacare.21.6.983
DO - 10.2337/diacare.21.6.983
M3 - Article
SN - 1935-5548
VL - 21
SP - 983
EP - 986
JO - Diabetes Care
JF - Diabetes Care
IS - 6
ER -