TY - JOUR
T1 - Erratum: High-Performance Unipolar n-Type Conjugated Polymers Enabled by Highly Electron-Deficient Building Blocks Containing F and CN Groups (Macromolecules (2022) 55:11 (4429−4440) DOI: 10.1021/acs.macromol.2c00870)
AU - Zhang, Chan
AU - Tan, Wen Liang
AU - Liu, Zhongwei
AU - He, Qiao
AU - Li, Yanru
AU - Ma, Jianeng
AU - Chesman, Anthony S.R.
AU - Han, Yang
AU - McNeill, Christopher R.
AU - Heeney, Martin
AU - Fei, Zhuping
N1 - Generated from Scopus record by KAUST IRTS on 2023-02-14
PY - 2022/7/26
Y1 - 2022/7/26
N2 - The full names of 2F2CNTVT and compound 4 in the original article were not correct, and the correct names are (E)-2,2′-(ethene-1,2-diyl)bis(4-fluorothiophene-3-carbonitrile) and (ethene-1,2-diyl)bis(4-fluoro-5-(triisopropylsilyl)- thiophene-3-carbaldehyde), respectively. The range of gate voltage (VGS) in some transfer characteristics for the plot of transfer curves (drain current IDSvs VGS) was incorrect. The error was generated during merging the transfer curve and IDS1/2vs VGScurve, and the Xaxis range of the two layers was not properly synchronized and caused the mismatch between the two layers in the plot (IDSvs VGSand IDS1/2vs VGS). Because IDS1/2vs VGScurves, which we used to extract mobilities and VTh, were properly plotted, the plotting problem does not affect the accuracy of any parameter values or the conclusions in the article. The corrected figures are given here.
AB - The full names of 2F2CNTVT and compound 4 in the original article were not correct, and the correct names are (E)-2,2′-(ethene-1,2-diyl)bis(4-fluorothiophene-3-carbonitrile) and (ethene-1,2-diyl)bis(4-fluoro-5-(triisopropylsilyl)- thiophene-3-carbaldehyde), respectively. The range of gate voltage (VGS) in some transfer characteristics for the plot of transfer curves (drain current IDSvs VGS) was incorrect. The error was generated during merging the transfer curve and IDS1/2vs VGScurve, and the Xaxis range of the two layers was not properly synchronized and caused the mismatch between the two layers in the plot (IDSvs VGSand IDS1/2vs VGS). Because IDS1/2vs VGScurves, which we used to extract mobilities and VTh, were properly plotted, the plotting problem does not affect the accuracy of any parameter values or the conclusions in the article. The corrected figures are given here.
UR - https://pubs.acs.org/doi/10.1021/acs.macromol.2c01353
UR - http://www.scopus.com/inward/record.url?scp=85135530283&partnerID=8YFLogxK
U2 - 10.1021/acs.macromol.2c01353
DO - 10.1021/acs.macromol.2c01353
M3 - Article
SN - 1520-5835
VL - 55
JO - Macromolecules
JF - Macromolecules
IS - 14
ER -