N2 - Microbial fuel cells (MFCs) and other bioelectrochemical systems are new technologies that require expertise in a variety of technical areas, ranging from electrochemistry to biological wastewater treatment. There are certain data and critical information that should be included in every MFC study, such as specific surface area of the electrodes, solution conductivity, and power densities normalized to electrode surface area and volumes. Electrochemical techniques such as linear sweep voltammetry can be used to understand the performance of the MFC, but extremely slow scans are required for these biological systems compared to more traditional fuel cells. In this Minireview, the critical information needed for MFC studies is provided with examples of how results can be better conveyed through a full description of materials, the use of proper controls, and inclusion of a more complete electrochemical analysis. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
AB - Microbial fuel cells (MFCs) and other bioelectrochemical systems are new technologies that require expertise in a variety of technical areas, ranging from electrochemistry to biological wastewater treatment. There are certain data and critical information that should be included in every MFC study, such as specific surface area of the electrodes, solution conductivity, and power densities normalized to electrode surface area and volumes. Electrochemical techniques such as linear sweep voltammetry can be used to understand the performance of the MFC, but extremely slow scans are required for these biological systems compared to more traditional fuel cells. In this Minireview, the critical information needed for MFC studies is provided with examples of how results can be better conveyed through a full description of materials, the use of proper controls, and inclusion of a more complete electrochemical analysis. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
UR - http://hdl.handle.net/10754/597969
UR - http://doi.wiley.com/10.1002/cssc.201100604
UR - http://www.scopus.com/inward/record.url?scp=84861840908&partnerID=8YFLogxK
U2 - 10.1002/cssc.201100604
DO - 10.1002/cssc.201100604
M3 - Article
C2 - 22517564
SN - 1864-5631
VL - 5
SP - 988
EP - 994
JO - ChemSusChem
JF - ChemSusChem
IS - 6
ER -