Flow control valves for analytical microfluidic chips without mechanical parts based on thermally responsive monolithic polymers

Cong Yu, Senol Mutlu, Ponnambalam Selvaganapathy, Carlos H. Mastrangelo, Frantisek Svec, Jean M.J. Fréchet*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

197 Scopus citations

Abstract

Monolithic plugs of poly(N-isopropylacrylamide) cross-linked with 5% methylenebisacrylamide have been prepared by photoinitiated polymerization within the channel of a microfluidic device. The volume change associated with the polymer phase transition at its lower critical solution temperature of 32 °C allows both the rapid swelling and the deswelling of the monoliths enabling the polymer to close or open the channel as it functions as a nonmechanical valve. Thermoelectric elements capable of changing the temperature of the system between 17 and 57 °C were used to actuate the valve. Flow through the device was monitored by fluorescence measurements via the laser-triggered photobleaching of a dye contained in the liquid phase. Photobleaching occurs quickly once the flow is stopped, and the time required to open and close the valve was 3.5 and 5.0 s, respectively. No changes in function were observed even after 120 open-close cycles. Although the 2-mm-long valve was prepared from a polymerization mixture consisting of only a 5% aqueous solution of monomers, it resists pressures of up to 1.38 MPa (200 psi) without observable structural damage.

Original languageEnglish (US)
Pages (from-to)1958-1961
Number of pages4
JournalANALYTICAL CHEMISTRY
Volume75
Issue number8
DOIs
StatePublished - Apr 15 2003
Externally publishedYes

ASJC Scopus subject areas

  • Analytical Chemistry

Fingerprint

Dive into the research topics of 'Flow control valves for analytical microfluidic chips without mechanical parts based on thermally responsive monolithic polymers'. Together they form a unique fingerprint.