@inproceedings{26196a01b0fb44a4b1d081b49e2c7398,
title = "Fouling of reverse osmosis membranes as investigated in a newly developed long channel RO test cell",
abstract = "• Validation (1): - Pressure drop and linear flow velocity meet theoretical characteristics - Reproducible for different pressures • Validation (2): - Plug flow with dispersion - CFD-model meets experimental data, no abnormal flow profile - Geometry of the inlet influences flow profile within first 50 mm • Fouling investigation: - Pressure drop increase of 4 test cells in series detectable, - Flux decline over segments.",
author = "N. Siebdrath and W. Ding and D. Diersche and E. Pietsch and A. Lerch and H. Vrouwenvelder and W. Uhl",
year = "2012",
language = "English (US)",
isbn = "9781622767878",
series = "Water Quality Technology Conference and Exposition 2012",
booktitle = "Water Quality Technology Conference and Exposition 2012",
note = "Water Quality Technology Conference and Exposition 2012 ; Conference date: 04-11-2012 Through 07-11-2012",
}