TY - JOUR
T1 - Full utilization of silt density index (SDI) measurements for seawater pre-treatment
AU - Wei, Chunhai
AU - Laborie, Stéphanie
AU - Ben Aïm, Roger M.
AU - Amy, Gary L.
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledgements: This work has been financed by European Union within the MEDINA (Membrane-Based Desalination: An Integrated Approach) Project (no. 036997). The authors also gratefully acknowledge Veolia Water for sampling seawater.
PY - 2012/7
Y1 - 2012/7
N2 - In order to clarify the fouling mechanism during silt density index (SDI) measurements of seawater in the seawater reverse osmosis (SWRO) desalination process, 11 runs were conducted under constant-pressure (207kPa) dead-end filtration mode according to the standard protocol for SDI measurement, in which two kinds of 0.45μm membranes of different material and seawater samples from the Mediterranean including raw seawater and seawater pre-treated by coagulation followed by sand filtration (CSF) and coagulation followed by microfiltration (CMF) technologies were tested. Fouling mechanisms based on the constant-pressure filtration equation were fully analyzed. For all runs, only t/(V/A)∼t showed very good linearity (correlation coefficient R 2>0.99) since the first moment of the filtration, indicating that standard blocking rather than cake filtration was the dominant fouling mechanism during the entire filtration process. The very low concentration of suspended solids rejected by MF of 0.45μm in seawater was the main reason why a cake layer was not formed. High turbidity removal during filtration indicated that organic colloids retained on and/or adsorbed in membrane pores governed the filtration process (i.e., standard blocking) due to the important contribution of organic substances to seawater turbidity in this study. Therefore the standard blocking coefficient k s, i.e., the slope of t/(V/A)∼t, could be used as a good fouling index for seawater because it showed good linearity with feed seawater turbidity. The correlation of SDI with k s and feed seawater quality indicated that SDI could be reliably used for seawater with low fouling potential (SDI 15min<5) like pre-treated seawater in this study. From both k s and SDI, the order of fouling potential was raw seawater>seawater pre-treated by CSF>seawater pre-treated by CMF, indicating the better performance of CMF than CSF. © 2012 Elsevier B.V.
AB - In order to clarify the fouling mechanism during silt density index (SDI) measurements of seawater in the seawater reverse osmosis (SWRO) desalination process, 11 runs were conducted under constant-pressure (207kPa) dead-end filtration mode according to the standard protocol for SDI measurement, in which two kinds of 0.45μm membranes of different material and seawater samples from the Mediterranean including raw seawater and seawater pre-treated by coagulation followed by sand filtration (CSF) and coagulation followed by microfiltration (CMF) technologies were tested. Fouling mechanisms based on the constant-pressure filtration equation were fully analyzed. For all runs, only t/(V/A)∼t showed very good linearity (correlation coefficient R 2>0.99) since the first moment of the filtration, indicating that standard blocking rather than cake filtration was the dominant fouling mechanism during the entire filtration process. The very low concentration of suspended solids rejected by MF of 0.45μm in seawater was the main reason why a cake layer was not formed. High turbidity removal during filtration indicated that organic colloids retained on and/or adsorbed in membrane pores governed the filtration process (i.e., standard blocking) due to the important contribution of organic substances to seawater turbidity in this study. Therefore the standard blocking coefficient k s, i.e., the slope of t/(V/A)∼t, could be used as a good fouling index for seawater because it showed good linearity with feed seawater turbidity. The correlation of SDI with k s and feed seawater quality indicated that SDI could be reliably used for seawater with low fouling potential (SDI 15min<5) like pre-treated seawater in this study. From both k s and SDI, the order of fouling potential was raw seawater>seawater pre-treated by CSF>seawater pre-treated by CMF, indicating the better performance of CMF than CSF. © 2012 Elsevier B.V.
UR - http://hdl.handle.net/10754/562225
UR - https://linkinghub.elsevier.com/retrieve/pii/S0376738812001913
UR - http://www.scopus.com/inward/record.url?scp=84859444512&partnerID=8YFLogxK
U2 - 10.1016/j.memsci.2012.03.010
DO - 10.1016/j.memsci.2012.03.010
M3 - Article
SN - 0376-7388
VL - 405-406
SP - 212
EP - 218
JO - Journal of Membrane Science
JF - Journal of Membrane Science
ER -