TY - JOUR
T1 - Impacts of operating conditions and solution chemistry on osmotic membrane structure and performance
AU - Wong, Mavis C.Y.
AU - Martinez, Kristina
AU - Ramon, Guy Z.
AU - Hoek, Eric M.V.
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledged KAUST grant number(s): KUS-C1-018-02
Acknowledgements: The work presented in this publication was supported by Award No. KUS-C1-018-02, made by King Abdullah University of Science and Technology (KAUST). GZR was supported by a Vaadia-BARD Post-doctoral Fellowship Award No. FI-435-2010 from BARD, The United States-Israel Binational Agricultural Research and Development Fund.
This publication acknowledges KAUST support, but has no KAUST affiliated authors.
PY - 2012/2
Y1 - 2012/2
N2 - Herein, we report on changes in the performance of a commercial cellulose triacetate (CTA) membrane, imparted by varied operating conditions and solution chemistries. Changes to feed and draw solution flow rate did not significantly alter the CTA membrane's water permeability, salt permeability, or membrane structural parameter when operated with the membrane skin layer facing the draw solution (PRO-mode). However, water and salt permeability increased with increasing feed or draw solution temperature, while the membrane structural parameter decreased with increasing draw solution, possibly due to changes in polymer intermolecular interactions. High ionic strength draw solutions may de-swell the CTA membrane via charge neutralization, which resulted in lower water permeability, higher salt permeability, and lower structural parameter. This observed trend was further exacerbated by the presence of divalent cations which tends to swell the polymer to a greater extent. Finally, the calculated CTA membrane's structural parameter was lower and less sensitive to external factors when operated in PRO-mode, but highly sensitive to the same factors when the skin layer faced the feed solution (FO-mode), presumably due to swelling/de-swelling of the saturated porous substructure by the draw solution. This is a first attempt aimed at systematically evaluating the changes in performance of the CTA membrane due to operating conditions and solution chemistry, shedding new insight into the possible advantages and disadvantages of this material in certain applications. © 2011 Elsevier B.V.
AB - Herein, we report on changes in the performance of a commercial cellulose triacetate (CTA) membrane, imparted by varied operating conditions and solution chemistries. Changes to feed and draw solution flow rate did not significantly alter the CTA membrane's water permeability, salt permeability, or membrane structural parameter when operated with the membrane skin layer facing the draw solution (PRO-mode). However, water and salt permeability increased with increasing feed or draw solution temperature, while the membrane structural parameter decreased with increasing draw solution, possibly due to changes in polymer intermolecular interactions. High ionic strength draw solutions may de-swell the CTA membrane via charge neutralization, which resulted in lower water permeability, higher salt permeability, and lower structural parameter. This observed trend was further exacerbated by the presence of divalent cations which tends to swell the polymer to a greater extent. Finally, the calculated CTA membrane's structural parameter was lower and less sensitive to external factors when operated in PRO-mode, but highly sensitive to the same factors when the skin layer faced the feed solution (FO-mode), presumably due to swelling/de-swelling of the saturated porous substructure by the draw solution. This is a first attempt aimed at systematically evaluating the changes in performance of the CTA membrane due to operating conditions and solution chemistry, shedding new insight into the possible advantages and disadvantages of this material in certain applications. © 2011 Elsevier B.V.
UR - http://hdl.handle.net/10754/598571
UR - https://linkinghub.elsevier.com/retrieve/pii/S0011916411008782
UR - http://www.scopus.com/inward/record.url?scp=84856583044&partnerID=8YFLogxK
U2 - 10.1016/j.desal.2011.10.013
DO - 10.1016/j.desal.2011.10.013
M3 - Article
SN - 0011-9164
VL - 287
SP - 340
EP - 349
JO - Desalination
JF - Desalination
ER -