TY - JOUR
T1 - Pressurized air cathodes for enhanced stability and power generation by microbial fuel cells
AU - He, Weihua
AU - Yang, Wulin
AU - Tian, Yushi
AU - Zhu, Xiuping
AU - Liu, Jia
AU - Feng, Yujie
AU - Logan, Bruce
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledged KAUST grant number(s): KUS-I1-003-13
Acknowledgements: The authors thank Dr. Xiaoyuan Zhang and David Jones for help with the manufacture of the reactor and analytical measurements. This research was supported by the Strategic Environmental Research and Development Program (SERDP), Award KUS-I1-003-13 from the King Abdullah University of Science and Technology (KAUST), the State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology (Grant No. 2013DX08), the National Natural Science Fund for Distinguished Young Scholars (Grant No. 51125033), and the International Cooperating Project between China and European Union (Grant No. 2014DFE90110) and a scholarship (No. 201206120191) to W.H. from the China Scholarship Council (CSC).
This publication acknowledges KAUST support, but has no KAUST affiliated authors.
PY - 2016/9/30
Y1 - 2016/9/30
N2 - Large differences between the water and air pressure in microbial fuel cells (MFCs) can deform and damage cathodes. To avoid deformation, the cathode air pressure was controlled to balance pressure differences between the air and water. Raising the air pressures from 0 to 10 kPa at a set cathode potential of −0.3 V (versus Ag/AgCl) enhanced cathode performance by 17%, but pressures ≥25 kPa decreased current and resulted in air leakage into the solution. Matching the air pressure with the water pressure avoided cathode deformation and improved performance. The maximum power density increased by 15%, from 1070 ± 20 to 1230 ± 70 mW m, with balanced air and water pressures of 10–25 kPa. Oxygen partial pressures ≥12.5 kPa in the cathode compartment maintained the oxygen reduction rate to be within 92 ± 1% of that in ambient air. The use of pressurized air flow through the cathode compartments can enable closer spacing of the cathodes compared to passive gas transfer systems, which could make the reactor design more compact. The energy cost of pressurizing the cathodes was estimated to be smaller than the increase in power that resulted from the use of pressurized cathodes.
AB - Large differences between the water and air pressure in microbial fuel cells (MFCs) can deform and damage cathodes. To avoid deformation, the cathode air pressure was controlled to balance pressure differences between the air and water. Raising the air pressures from 0 to 10 kPa at a set cathode potential of −0.3 V (versus Ag/AgCl) enhanced cathode performance by 17%, but pressures ≥25 kPa decreased current and resulted in air leakage into the solution. Matching the air pressure with the water pressure avoided cathode deformation and improved performance. The maximum power density increased by 15%, from 1070 ± 20 to 1230 ± 70 mW m, with balanced air and water pressures of 10–25 kPa. Oxygen partial pressures ≥12.5 kPa in the cathode compartment maintained the oxygen reduction rate to be within 92 ± 1% of that in ambient air. The use of pressurized air flow through the cathode compartments can enable closer spacing of the cathodes compared to passive gas transfer systems, which could make the reactor design more compact. The energy cost of pressurizing the cathodes was estimated to be smaller than the increase in power that resulted from the use of pressurized cathodes.
UR - http://hdl.handle.net/10754/624963
UR - https://linkinghub.elsevier.com/retrieve/pii/S0378775316313015
UR - http://www.scopus.com/inward/record.url?scp=84989172233&partnerID=8YFLogxK
U2 - 10.1016/j.jpowsour.2016.09.112
DO - 10.1016/j.jpowsour.2016.09.112
M3 - Article
SN - 0378-7753
VL - 332
SP - 447
EP - 453
JO - Journal of Power Sources
JF - Journal of Power Sources
ER -