TY - JOUR
T1 - Red/NIR/SWIR multi-band persistent probe chargeable by general lighting sources for long-term, high-contrast visible/NIR-I/NIR-II multi-window bioimaging
AU - Chen, Yafei
AU - Spinelli, Simona
AU - Gu, Zhanjun
AU - Pan, Zhengwei
N1 - KAUST Repository Item: Exported on 2022-06-23
Acknowledgements: The authors thank Stefano Mandaglio and Riccardo Rivolta from the KAUST Animal Resources Core Lab for their assistance with the mouse bioimaging experiments.
PY - 2022/6/14
Y1 - 2022/6/14
N2 - Persistent luminescence-based bioimaging affords high-contrast, deep-tissue imaging, but suffers from short imaging duration (a few minutes to a few hours), gradually diminishing emission intensity and imaging quality during imaging, being non-rechargeable in vivo, and single emission band (visible, near-infrared (NIR, 700–950 nm), or short-wave infrared (SWIR, 950–1700 nm)). Here, we report a CaTiO3:Pr3+ multi-band persistent probe that is chargeable by extremely-weak visible light such as moonlight, and simultaneously emit red (610 nm), NIR (893 nm) and SWIR (1040 nm) persistent luminescence. This red/NIR/SWIR multi-band persistent probe allows the first-ever bioimaging in all three bioimaging windows (visible, NIR-I (700–950 nm) and NIR-II (1000–1350 nm)) using one probe under same imaging condition. The probe is chargeable by tissue-friendly, low-intensity general lighting sources (e.g., a household white LED bulb) through deep organs (e.g., stomach, liver, lungs) of live mice at any time points during imaging, affording consistent emission intensity and imaging quality over an unlimited imaging time. These unique bioimaging features, along with other important findings regarding tissue attenuation of red, NIR and SWIR light, imaging factors-dependent signal-to-background ratios and persistent luminescence-based NIR-II bioimaging, are expected to impact not only persistent luminescence-based bioimaging but also optical bioimaging in general.
AB - Persistent luminescence-based bioimaging affords high-contrast, deep-tissue imaging, but suffers from short imaging duration (a few minutes to a few hours), gradually diminishing emission intensity and imaging quality during imaging, being non-rechargeable in vivo, and single emission band (visible, near-infrared (NIR, 700–950 nm), or short-wave infrared (SWIR, 950–1700 nm)). Here, we report a CaTiO3:Pr3+ multi-band persistent probe that is chargeable by extremely-weak visible light such as moonlight, and simultaneously emit red (610 nm), NIR (893 nm) and SWIR (1040 nm) persistent luminescence. This red/NIR/SWIR multi-band persistent probe allows the first-ever bioimaging in all three bioimaging windows (visible, NIR-I (700–950 nm) and NIR-II (1000–1350 nm)) using one probe under same imaging condition. The probe is chargeable by tissue-friendly, low-intensity general lighting sources (e.g., a household white LED bulb) through deep organs (e.g., stomach, liver, lungs) of live mice at any time points during imaging, affording consistent emission intensity and imaging quality over an unlimited imaging time. These unique bioimaging features, along with other important findings regarding tissue attenuation of red, NIR and SWIR light, imaging factors-dependent signal-to-background ratios and persistent luminescence-based NIR-II bioimaging, are expected to impact not only persistent luminescence-based bioimaging but also optical bioimaging in general.
UR - http://hdl.handle.net/10754/679240
UR - https://linkinghub.elsevier.com/retrieve/pii/S1385894722029618
UR - http://www.scopus.com/inward/record.url?scp=85131965298&partnerID=8YFLogxK
U2 - 10.1016/j.cej.2022.137473
DO - 10.1016/j.cej.2022.137473
M3 - Article
SN - 1385-8947
VL - 446
SP - 137473
JO - Chemical Engineering Journal
JF - Chemical Engineering Journal
ER -