The Membrane Fouling Simulator as a new tool for biofouling control of spiral-wound membranes

J. S. Vrouwenvelder*, S. M. Bakker, L. P. Wessels, J. A.M. van Paassen

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

69 Scopus citations

Abstract

Studies with a new tool - the Membrane Fouling Simulator (MFS) - illustrate that the MFS can be used to quantify and characterize fouling. Using the MFS, fouling can be monitored by (1) operational parameters like pressure drop, (2) non-destructive (visual, microscopic) observations using the sight glass and (3) analysis of coupons sampled from the membrane sheet in the MFS. The small scale of the MFS makes it easy to handle and requires small amounts of water and chemicals, enhancing the possibility to test several MFS units in parallel. A comparison study of the MFS and spiral-wound membrane modules showed the same fouling. The MFS is representative for spiral membrane elements, indicating that the MFS is suitable to study and monitor biofouling.

Original languageEnglish (US)
Pages (from-to)170-174
Number of pages5
JournalDesalination
Volume204
Issue number1-3 SPEC. ISS.
DOIs
StatePublished - Feb 5 2007
Externally publishedYes

Keywords

  • (Bio)fouling
  • Cleaning
  • Membrane fouling simulator
  • Nanofiltration
  • Reverse osmosis

ASJC Scopus subject areas

  • General Chemistry
  • Water Science and Technology
  • General Chemical Engineering
  • Mechanical Engineering
  • General Materials Science

Fingerprint

Dive into the research topics of 'The Membrane Fouling Simulator as a new tool for biofouling control of spiral-wound membranes'. Together they form a unique fingerprint.

Cite this