TY - GEN
T1 - The vitruvian baby: Interactive reformation of fetal ultrasound data to a T-position
AU - Mörth, Eric
AU - Raidou, Renata G.
AU - Viola, Ivan
AU - Smit, Noeska N.
N1 - KAUST Repository Item: Exported on 2020-10-01
Acknowledgements: This research was partially supported by the Trond Mohn Foundation (grant number’811255’).
PY - 2019/1/1
Y1 - 2019/1/1
N2 - Three-dimensional (3D) ultrasound imaging and visualization is often used in medical diagnostics, especially in prenatal screening. Screening the development of the fetus is important to assess possible complications early on. State of the art approaches involve taking standardized measurements to compare them with standardized tables. The measurements are taken in a 2D slice view, where precise measurements can be difficult to acquire due to the fetal pose. Performing the analysis in a 3D view would enable the viewer to better discriminate between artefacts and representative information. Additionally making data comparable between different investigations and patients is a goal in medical imaging techniques and is often achieved by standardization. With this paper, we introduce a novel approach to provide a standardization method for 3D ultrasound fetus screenings. Our approach is called “The Vitruvian Baby” and incorporates a complete pipeline for standardized measuring in fetal 3D ultrasound. The input of the method is a 3D ultrasound screening of a fetus and the output is the fetus in a standardized T-pose. In this pose, taking measurements is easier and comparison of different fetuses is possible. In addition to the transformation of the 3D ultrasound data, we create an abstract representation of the fetus based on accurate measurements. We demonstrate the accuracy of our approach on simulated data where the ground truth is known.
AB - Three-dimensional (3D) ultrasound imaging and visualization is often used in medical diagnostics, especially in prenatal screening. Screening the development of the fetus is important to assess possible complications early on. State of the art approaches involve taking standardized measurements to compare them with standardized tables. The measurements are taken in a 2D slice view, where precise measurements can be difficult to acquire due to the fetal pose. Performing the analysis in a 3D view would enable the viewer to better discriminate between artefacts and representative information. Additionally making data comparable between different investigations and patients is a goal in medical imaging techniques and is often achieved by standardization. With this paper, we introduce a novel approach to provide a standardization method for 3D ultrasound fetus screenings. Our approach is called “The Vitruvian Baby” and incorporates a complete pipeline for standardized measuring in fetal 3D ultrasound. The input of the method is a 3D ultrasound screening of a fetus and the output is the fetus in a standardized T-pose. In this pose, taking measurements is easier and comparison of different fetuses is possible. In addition to the transformation of the 3D ultrasound data, we create an abstract representation of the fetus based on accurate measurements. We demonstrate the accuracy of our approach on simulated data where the ground truth is known.
UR - http://hdl.handle.net/10754/664462
UR - https://diglib.eg.org/handle/10.2312/vcbm20191245
UR - http://www.scopus.com/inward/record.url?scp=85087463130&partnerID=8YFLogxK
U2 - 10.2312/vcbm.20191245
DO - 10.2312/vcbm.20191245
M3 - Conference contribution
SN - 9783038680819
SP - 201
EP - 205
BT - 2019 Eurographics Workshop on Visual Computing for Biology and Medicine, VCBM 2019
PB - Eurographics Association
ER -