TY - JOUR
T1 - Use of expanded polystyrene wastes in developing hollow block masonry units
AU - Ali, Youmna A.Y.
AU - Fahmy, Ezzat H.A.
AU - AbouZeid, Mohamed N.
AU - Shaheen, Yoursy B.I.
AU - Mooty, Mohamed N.Abdel
N1 - KAUST Repository Item: Exported on 2022-06-13
Acknowledgements: This publication is based on work supported by King Abdullah University of Science and Technology (KAUST), KSA and the American University in Cairo (AUC), Egypt.
This publication acknowledges KAUST support, but has no KAUST affiliated authors.
PY - 2020/1/17
Y1 - 2020/1/17
N2 - This paper presents the results of an experimental investigation aimed at developing lightweight hollow block masonry units of adequate mechanical and durability characteristics for applications in the construction industry. Five dosages of EPS crumbles were used as partial replacement of the sand in the blocks mixture, namely; 0%, 10%, 15%, 20%, and 26%. Skin reinforcement was added to some of the tested. Three types of EPS blocks were tested: 1 – plain blocks without reinforcement, 2 – blocks reinforced with welded steel wire mesh, and 3 – blocks reinforced with fiberglass mesh. The density of the developed blocks ranged between 2119 and 982 kg/m3 and the net area compressive strength ranged between 9.5 and 1.4 MPa. The presence of EPS in the mixture greatly improved the failure pattern of all the EPS hollow blocks. The durability tests proved that EPS hollow blocks were resilient to acid and salt exposure. The weight loss and compressive strength loss of the hollow blocks due to ettringite leach decreased significantly with the addition of EPS. The presence of the skin reinforcement had minimal effect on the compressive strength, but it improved the failure pattern. The developed EPS hollow blocks are suitable for non-load bearing application of exterior and interior walls within the stated limits of ASTM and the Egyptian Standards.
AB - This paper presents the results of an experimental investigation aimed at developing lightweight hollow block masonry units of adequate mechanical and durability characteristics for applications in the construction industry. Five dosages of EPS crumbles were used as partial replacement of the sand in the blocks mixture, namely; 0%, 10%, 15%, 20%, and 26%. Skin reinforcement was added to some of the tested. Three types of EPS blocks were tested: 1 – plain blocks without reinforcement, 2 – blocks reinforced with welded steel wire mesh, and 3 – blocks reinforced with fiberglass mesh. The density of the developed blocks ranged between 2119 and 982 kg/m3 and the net area compressive strength ranged between 9.5 and 1.4 MPa. The presence of EPS in the mixture greatly improved the failure pattern of all the EPS hollow blocks. The durability tests proved that EPS hollow blocks were resilient to acid and salt exposure. The weight loss and compressive strength loss of the hollow blocks due to ettringite leach decreased significantly with the addition of EPS. The presence of the skin reinforcement had minimal effect on the compressive strength, but it improved the failure pattern. The developed EPS hollow blocks are suitable for non-load bearing application of exterior and interior walls within the stated limits of ASTM and the Egyptian Standards.
UR - http://hdl.handle.net/10754/678932
UR - https://linkinghub.elsevier.com/retrieve/pii/S0950061820301549
UR - http://www.scopus.com/inward/record.url?scp=85077933881&partnerID=8YFLogxK
U2 - 10.1016/j.conbuildmat.2020.118149
DO - 10.1016/j.conbuildmat.2020.118149
M3 - Article
SN - 0950-0618
VL - 241
SP - 118149
JO - Construction and Building Materials
JF - Construction and Building Materials
ER -